ABB's MS116 starter: a thermal trip that can stick when overloaded

Nonconforming parts can jam the bimetal and trip mechanism — no thermal trip on overload, overheating risk. Korea recall 4 Aug 2026; inspect, replace or return.

ABB · 2026-08-04

What happened

ABB Korea recalled manual motor starters MS116 (0.63A to 12A — the 1.6, 2.5, 4.0, 6.3 and 10A ratings) made in date codes W2615 to W2618, listed in Korea on August 4, 2026: nonconforming internal components can degrade the bimetal and stick the trip mechanism.

With the thermal trip stuck, an overload heats the starter instead of cutting it — property and personal-injury risk where the starters protect motors in panels and machines. No incident was reported; the risk came out of ABB's own assessment.

Owners stop use and contact ABB Korea for inspection, replacement or return — four weeks of production, pulled at the spring.

Why it happened

  • Nonconforming internal components can stick the trip mechanism — no thermal trip on overload, overheating risk; Korea recall Aug 4, 2026, date codes W2615–W2618
  • The starter is the motor's fuse with a reset button — when its trip sticks, the overload burns everything downstream
  • Found by risk assessment, not by fire — four production weeks pulled before the first incident
What it costOverload protection that can't tripcostly

The lesson

A motor starter's whole value is the trip that ends a bad hour. Four date codes with a stuck mechanism are a reminder that the protector is a product too, with its own bad weeks.