The encyclopedia · Engineering & Operations · Technical decision · 1968–1970
A gas explosion in a London tower blew out a wall — and the whole corner collapsed
A 1968 gas explosion in Ronan Point's 18th floor kitchen blew out a wall. The panel system was not robust enough — the corner fell like a house of cards.
Taylor Woodrow Anglian · Greater London Council · Ronan Point · 1968-05-16
What happened
Ronan Point was a 22-story apartment tower in Newham, London, built using a 'system-built' large panel construction method — precast concrete walls and floors stacked like a house of cards. The building was part of a wave of affordable housing built in the 1960s using industrial methods. The system was fast and cheap, but had never been tested for gas explosion resistance.
On May 16, 1968, a gas explosion in the 18th floor kitchen blew out an external load-bearing wall panel. The floor above was left unsupported, collapsed, and the failure cascaded down — the entire southeast corner of the building collapsed. Four people were killed and 17 were injured. The damage was contained to one corner, but the building was structurally compromised.
The investigation found that the panel construction system lacked robustness: the joints between panels were not strong enough to transfer loads after a local failure. The building had no secondary load paths — if one panel failed, the structure above had nothing to hold it. The collapse led to changes in British building codes, requiring that buildings be designed to withstand a local failure without disproportionate collapse.
Why it happened
- The large panel system connected precast concrete walls with simple joints that could not transfer loads after a local failure — there were no secondary load paths.
- The building was designed for normal loads only, without considering what would happen if a single load-bearing element was removed by an explosion or impact.
- The construction method prioritized speed and cost over structural robustness — the 'house of cards' design was acceptable because nobody had considered the unthinkable.
The lesson
A building that has no secondary load paths is not a building — it is a house of cards. The question is not whether the first panel will fail, but whether anything is holding the next one.
Sources
- Griffiths Report (1968) — Report of the Inquiry into the Collapse of Flats at Ronan Point, Canning Town (Ministry of Housing and Local Government; via Internet Archive)
- BBC On This Day (16 May 1968) — Gas blast wrecks London tower block
- Ronan Point — Wikipedia
spotted an error? The club wants to know.
More like this
The new Wembley cost £798M — 2.4x the budget — and the roof doesn't work
The Channel Tunnel cost £9B — 64% over budget — with half the projected traffic
The Titanic carried lifeboats for 1,178 — and there were 2,224 people on board
Somewhere, someone solved the problem this company failed at. 2nd Opinion →